Lesson 1

Entrapment Device Types & Classifications

What Is Entrapment Protection

Entrapment protection prevents a closing garage door from trapping a person, animal, or object. Canadian standards require that every power-operated garage door have at least one entrapment protection device. The specific requirements depend on the type of door, its application, and the control system used.

Primary Devices

Photoelectric sensors - infrared beam across the opening

Sensing edges - pressure-sensitive strip on door bottom

Constant-pressure controls - door moves only while button is held

Secondary Device

Auto-reverse mechanism - built-in force-sensing reversal

Required on all residential openers as a secondary backup

Must reverse door within 2 seconds of obstruction contact

Classification Under CSA C260

CSA C260 classifies entrapment protection devices into categories:

  • Type A - External entrapment protection that detects an obstruction before the door contacts it (photo eyes, light curtains)
  • Type B - Contact-type protection that detects an obstruction when the door touches it (sensing edges, auto-reverse)
  • Constant-pressure - Not a detection device per se, but a control method that requires continuous operator input

Monitored vs. Non-Monitored Systems

Monitored entrapment protection systems continuously verify that the safety device is connected and functional. If a wire is cut or a sensor fails, the system detects the fault and prevents automatic door operation. CSA standards increasingly require monitored systems for new installations.

✅

Exam Distinction

The exam will test whether you understand the difference between monitored and non-monitored systems. A monitored system detects sensor failure and prevents operation; a non-monitored system may continue operating even if a sensor is disconnected.

Key Takeaway

CSA C260 requires entrapment protection on all power-operated garage doors. Type A devices (photo eyes) detect obstructions before contact; Type B devices (sensing edges) detect on contact. Monitored systems verify sensor integrity and prevent operation if a sensor fails.